Sharp XG-PH80W-N Projector User Manual


 
68
5
Insert the new lamp unit.
Press the lamp unit fi rmly into the lamp unit
compartment. Fasten the securing screw.
6
Replace the lamp unit cover.
Align the lamp unit cover and slide it to
close (1). Then tighten the user service
screw (2) to secure the lamp unit cover.
Info
If the lamp unit and lamp unit cover
are not correctly installed, the power
will not turn on, even if the power
cord is connected to the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Info
Make sure to reset the lamp timer only when
replacing the lamp. If you reset the lamp timer
and continue to use the same lamp, this may
cause the lamp to become damaged or explode.
You can reset the lamp timer only when
“STANDBY mode” is set to “Standard”.
1
Connect the power cord and
switch the MAIN POWER switch
on the projector to “ON”.
Plug the power cord into the AC socket of
the projector.
2
Reset the lamp timer.
The projector enters Standby mode when
you reset the lamp timer.
For Lamp 1
When you reset the timer, press MENU
ENTER ENTER MENU O
STANDBY/ON on the projector.
“LAMP1 0000H” is displayed, indicating
that the lamp timer is reset.
For Lamp 2
When you reset the timer, press MENU
ENTER ENTER MENU Q
STANDBY/ON on the projector.
“LAMP2 0000H” is displayed, indicating
that the lamp timer is reset.
5
6
AC socketAC socket
1
2
ENTER button
MENU button
O/Q buttons
STANDBY/ON
button
ENTER button
MENU button
O/Q buttons
STANDBY/ON
button
Regarding the Lamp (Continued)