Sigma projetor Projector User Manual


 
DAILY INSPECTION INSTRUCTIONS
3.9
d. A final check of the control cable connector and source assembly connector is accomplished by
use of a Model 550 NO GO gauge to check for significant wear on the connectors that would
affect safety. Without using excessive force, check the following four positions (see figure 3.5):
1 Ball at the end of the control cable connector must NOT GO into the hole of the gauge.
2 The shank or stem of the control cable connector must NOT GO into the smaller of the
two notches located on the side of the gauge.
3 The width of the gauge must NOT GO into the female slot of the source assembly
connector.
4 After a positive connection between the control cable and source assembly connectors
has been accomplished, verify that the larger notch located on the side of the gauge will
NOT GO in the gap between the joined connectors.
Replace any components that fail any of the NO GO gauge tests, because a failure indicates
significant wear that could allow safety features of the design to be defeated.
IMPORTANT REMINDER
Do not compromise on safety. Always perform a daily inspection of the exposure device,
projection sheaths and remote controls prior to use.
Defective equipment that is discovered during the daily inspection must be removed from
service until repaired or replaced.
Figure 3.5 No-Go gauge tests
1. Ball Diameter
2. Ball Shank
4. Connector
Gap Width
3.Female Slot Width