Seiko Instruments G1216B1N000 Computer Monitor User Manual


 
AN.No.G1216B1N000-3D0E
- 19 -
(3) X-address (page) set
DB
0
Code
D/I DB
7
1 0 1 1 1 A A A
R/W
0 0
Upper bits
Lower bits
The display data RAM “X” address (page) which is expressed with binary AAA is set in the X-address
register. Following write/read operations from the MPU are performed on the specified X-address
(page) until the next X-address (page) set is performed. The configuration of display data RAM and
X-address is shown in Figure 9.
DB
0
Code
D/I DB
7
0 1 A A A A A A
R/W
0 0
Upper bits Lower bits
(4) Y-address set
The display data RAM Y- address which is expressed with binary AAAAAA is set in the Y-address
counter. After that the Y-address counter advances by one each time write/read is performed from
the MPU. The configuration of the display data RAM and Y-address is shown in Figure 9.
Page 0
Y-address
DB
0
to
DB
7
X=0
Page
1
DB
0
to
DB
7
X=1
Page 6
DB
0
to
DB
7
X=6
Page 7
DB
0
to
DB
7
X=7
01234---------------616263
Figure 9 Display Data RAM Address Configuration