SMC Networks SMC 6000A Power Supply User Manual


 
SMA Technologie AG Electrical Connection
Installation Guide SMC50A_60A-IEN073320 Page 29
6 Connect up the faultless PV generator strings
as indicated on the right.
7 Close the unused DC input sockets with the caps included in the delivery.
8 Reinsert the handle of the Electronic Solar
Switch in the socket on the underside of the
Sunny Mini Central.
The Electronic Solar Switch can be damaged if it has not
been attached properly. The handle must be firmly attached
to the Electronic Solar Switch's socket, and rest against the
housing. Check that the handle is positioned correctly
before recommissioning the inverter.
Step Instruction