Spectrum Signal Processing Monaco Technical Reference
Registers
Part Number 500-00191
49
Revision 2.00
VINTA Register
Address: 016D 8004h
D31.. ..D8
Reserved
D7.. ..D1 D0
Reserved Interrupt
This register allows any processor to generate or clear an interrupt to node A. Upon reset
this value is ‘0’.
• To generate an interrupt to node A, set bit D0 of this register to “1”.