APPENDIX
Available DIP switch settings (Parallel Interface)
The following table shows all the possible settings for the DIP switch. The
factory default settings are ON for switches 1 through 7 and OFF for switch 8.
A reset can be performed with pin 31 on the interface by setting DIP switch 1 to
ON (the factory default setting).
In addition, when a reset can be performed with pin 31, setting DIP switch 2 to
OFF sets up the unit to perform a reset when pin 31 and pin 36 are “LOW”.
*1: Never set switch 7 to OFF at the same time that switch 8 is set to ON.
Switch Parameter ON OFF
1
Pin 31 / Pin 36 Reset Signal See table below.
2
3
Not used (Always ON)
4
5
6
7
Command Emulation See table below.
8
Reset Signal Switch 1 Switch 2
Pin 31 is enabled. ON ON
Pin 31/Pin 36 are enabled. ON OFF
Disabled OFF ON
Disabled OFF OFF
Command Emulation Switch 7 Switch 8
Star mode ON ON
ESC/POS (TM-295) ON OFF
ESC/POS (TM-290) OFF OFF
Not used (*1) OFF ON