Sun Microsystems 880 Server User Manual


 
16 Sun Fire 880 Server Product Notes December 2001
The table for CPU Side Components transposes the part numbers for items 2
though 4. The corrected part numbers are as follows.
Correction to Cabling Instructions for Loop B PCI
FC-AL Data Cable
The cabling instructions for the Loop B PCI FC-AL data cable are incorrect due to a
late change to the labeling scheme on the cable’s connectors.
The correct cabling information is provided below.
Note that the following sections of the Sun Fire 880 Server Service Manual are affected
by this change:
“How to Install the Sun StorEdge PCI Dual Fibre Channel Host Adapter Card”
“Cable Routing”
Correction to Expansion FC-AL Backplane
Installation Procedure
The procedure “How to Install the Expansion FC-AL Backplane” as documented in
the Sun Fire 880 Server Service Manual is incomplete. The following should be
included in the procedure before the reconfiguration boot instructions in the “What
Next” section.
1. After installing an expansion backplane, power on the system and bring the
system up to the ok prompt.
Key Description Part Number
2 CPU/Memory Board Status Assembly 540-4454
3 CPU Fan Tray 540-3614
4 CPU/Memory Board Air Baffle 540-4431
Cable Name Part Number Cable End Connect To
Loop B PCI FC-AL data cable 530-3056 D
C
P3
P4
Base backplane at D
Base backplane at C
PCI card at J3
PCI card at J4