SUPER MICRO Computer 2042G-TRF Server User Manual


 
Chapter 5: Advanced Serverboard Setup
5-15
Power LED Connector
The Power LED connector is on pins 15 and
16 of JF1. See the table on the right for pin
de nitions.
Power LED
Pin De nitions
(JF1)
Pin# De nition
15 PW_ON
16 Ground
HDD/FP UID Switch
The HDD/UID Switch connections are
located on pins 13/14 of JF1. Attach a
hard-drive LED cable to display HDD or
SATA activities. This connection can also
be used as a front panel UID (Unit Identi
er) switch. The UID LED on Pin 7 of JF1
works in conjunction with this UID Switch.
When the user presses and releases the UID
switch, the UID LED will be turned on or off
to indicate the location of the unit. (Refer to
Page 2-11 for more details.)
HDD/UID Switch
Pin De nitions
(JF1)
Pin# De nition
13 UID Signal/3.3V
14 HDD Active
Overheat (OH)/Fan Fail/PWR Fail/UID
LED
Connect an LED cable to pins 7 and 8 of
JF1 to use the Overheat/Fan Fail/Power Fail
and UID LED connections. The Red LED on
pin 8 provides warnings of an overheat, fan
failure or power failure. The Blue LED on pin
7 works as the UID LED indicator for the front
panel UID switch located on pins 13~14 of
JF1. When Jumper J_UID_OW is set to off
(default), the Red LED takes precedence
over the Blue LED. (See Page 2-19 for
details.) Refer to the table on the right for
pin de nitions.
OH/Fan Fail/ PWR Fail/Blue_UID
LEDPin De nitions (JF1)
Pin# De nition
7 Blue_LED-Cathode(UID)/5.5V.SB
8 OH/Fan Fail/PWR Fail/UID LED
(Red)
OH/Fan Fail/PWR Fail
LED Status (Red LED)
State Indication
Off Normal
On Overheat
Flashing Fan Fail
Power Fail LED
The Power Fail LED connection is located on
pins 5 and 6 of JF1. Refer to the table on the
right for pin de nitions.
PWR Fail LED
Pin De nitions
(JF1)
Pin# De nition
5 3.3V
6 PWR Fail LED