SUPER MICRO Computer 6015TC-10G Server User Manual


 
C-2
SUPERSERVER 6015TC-T/6015TC-10G User's Manual
Weight
Gross Weight: 40 lbs. (18.2 kg.)
System Cooling
Six (6) high-performance 4-cm PWM (Pulse Width Modulated) fans
System Input Requirements
AC Input Voltage: 100 - 240V AC auto-range
Rated Input Current: 9.5 - 6A max @ 700W, 5 - 3.5A @ 780W*
Rated Input Frequency: 50 to 60 Hz
*Power supply operates at 700W with a 100-140V input and at 780W with a 180-
240W input
Power Supply
Rated Output Power: 700W (Part# PWS-781-1S)
Rated Output Voltages: +12V (81A), +5Vsb (4A)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions:
FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
Electromagnetic Immunity:
EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety:
EN 60950/IEC 60950-Compliant
UL Listed (USA)
CUL Listed (Canada)
TUV Certi ed (Germany)
CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate”