SUPER MICRO Computer AOC-SOZCR1 Computer Hardware User Manual


 
Chapter 3: RAID Confi guration
3-15
Rebuilding Arrays
Note: If there is an interruption during array building or disk initialization, you
can rebuild an array. You can only confi gure RAID 1 for array rebuild. If a hard
disk fails and there is no hot spare array available, you will need to create a hot
spare drive fi rst before creating an array. (Refer to "Creating HotSpare Drives"
for more information.)
To Rebuild an array:
1. From the main menu, select Manage Arrays. From the list of arrays, select
the array you want to rebuild.
2. Press <Ctrl> and <R> simultaneously to rebuild an array.
To Rescan Disk drives
1. Power on your system. When prompted, press <Ctrl> and <A> simultane-
ously to access the Array Confi guration Utility.
2. When the Array Confi guration Utility Main Menu appears, select "Array Con-
guration Utility" and press <Enter>. The following screen will display:
3. From the Array Confi guration Main Menu appears, select "Rescan Drives" and
press <Enter>. The Array Confi guration Utility starts to rescan the selected disk
drives as shown in the screen on the next page: