SUPER MICRO Computer MIIC-203 Network Card User Manual


 
32
iPort/AFM
ASCII Text Interface Commands
Note: [CR] = Carriage Return Code or Enter Key.
Syntax: [Select], (Optional), xx = [00..FE], n = [0..32767]
Command Description
Ctrl/R,Ctrl/R,Ctrl/R
iPort/AFM Reset
This command resets the iPort/AFM to its default state.
//[CR]
Status Display
Display iPort/AFM status information.
/B[0|1|2][CR]
RS-232 Baud Rate Control
Set the RS-232 Baud rate (0 = 19.2, 1 = 57.6, 2 = 115.2 Baud)
/C[CR]
Close I
2
C Connection
Disconnect from the I
2
C Bus.
/Dxx[CR]
Set Destination I
2
C Slave Address
Set the destination I
2
C Slave Address for subsequent Master Transmit or
Receive operations.
/E[0|1][CR]
Echo/Prompt Control [0 = Disable, 1 = Enable]
Enable/Disable data entry echo and prompts.
/F[0|1][CR]
Flow Control [0 = XON/XOFF, 1 = RTS/CTS]
Select serial communication handshaking protocol.
/G[0|1][CR]
I
2
C General Call Control [0 = Disable, 1 = Enable]
Enables/Disables iPort/AFM response to I
2
C Bus General Call (00)
messages.
/H[0|1][CR]
Hex Only Display Control [0 = Disable, 1 = Enable]
Controls display format of received message data.
/Ixx[CR]
Set iPort/AFMs Own I
2
C Slave Address
Sets iPort/AFM's own I
2
C Slave Address. iPort/AFM will respond to I
2
C
Bus messages sent to this address.
/K[0|1|2|3][CR]
I
2
C Bus Clock Rate Control
Set I
2
C Bus Clock Rate Control
(0=23, 1=86, 2=100, 3=400 KHz)
/M[CR]
Command Menu Display
Display iPort/AFM's Command Menu