Symbol Technologies DS 6608 Scanner User Manual


 
DS 6608 Product Reference Guide13-28
Clear Transmission Buffer
To clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character, a dash (minus), and a
stop character.
The digital scanner issues a short hi/lo/hi beep.
The digital scanner erases the transmission buffer.
No transmission occurs.
The Clear Buffer contains only the dash (minus) character. In order to scan this command, be sure Code 39
length is set to include length 1.
Transmit Buffer
There are two methods to transmit the Code 39 buffer.
1. Scan the Transmit Buffer bar code below. Only a start character, a plus (+), and a stop character.
The digital scanner transmits and clears the buffer.
The digital scanner issues a Lo/Hi beep.
2. Scan a Code 39 bar code with a leading character other than a space.
The digital scanner appends new decode data to buffered data.
The digital scanner transmits and clears the buffer.
The digital scanner signals that the buffer was transmitted with a lo/hi beep.
Digital Scanner transmits and clears the buffer.
The Transmit Buffer contains only a plus (+) character. In order to scan this command, be sure Code 39 length
is set to include length 1.
Clear Buffer
Transmit Buffer
Note
Note