DS 6608 Product Reference Guide4-8
Time Delay to Low Power Mode
Parameter # 92h
This parameter only applies when Power Mode is set to Reduced Power.
This parameter sets the time the digital scanner remains active after decoding. The digital scanner wakes upon trigger pull or when
the host attempts to communicate with the digital scanner.
1 Second
(11h)
5 Seconds
(15h)
1 Minute
(21h)
*5 Minutes
(25h)
Note