Symbol Technologies LS 2106 Scanner User Manual


 
3-7
Maintenance and Specifications
Beeper Indications
Standard Use
Beeper Sequence Indication
Short high tone A bar code symbol was decoded (if decode beeper is
enabled).
4 Beeps - long low tone A transmission error has been detected in a scanned
symbol. The data is ignored. This will occur if a unit is
not properly configured. Check option settings.
5 Beeps - low tone Convert or format error
Lo/hi/lo tone ADF transmit error
Hi/hi/hi/lo tone RS-232 receive error
Parameter Menu Scanning
Short high tone Correct entry scanned or correct menu sequence
performed.
Lo/hi tone Input error, incorrect bar code or “Cancel” scanned,
wrong entry, incorrect bar code programming sequence;
remain in program mode.
Hi/lo tone Keyboard parameter selected. Enter value using bar code
keypad.
Hi/lo/hi/lo tone Successful program exit with change in the parameter
setting.
Code 39 Buffering
Hi/lo tone New Code 39 data was entered into the buffer.
3 Beeps - long high tone Code 39 buffer is full.
Lo/hi/lo tone The buffer was erased, or there was an attempt to
transmit an empty buffer. When the Code 39 buffer was
empty, the scanner read a command to clear or to
transmit a Code 39 buffer.
4 Beeps - long low tone Error in data transmission.
Lo/hi tone A successful transmission of buffered data.