Table A-1. Reading Standard Code128 & UCC/EAN 1 2 8
Standard
Code 128
UCC/EAN-128 Effect and Example
Disable Disable No Code 128 symbols can be read.
Disable Enable Read only symbols with leading FNC 1.
Examples:
FNC1
ABCD
FNC1
E will be read as ABCD
29
E
A
FNC1
BCD
FNC1
E will be read as ABCD
29
E
FNC1FNC1
ABCD
FNC1
E will be read as ABCD
29
E
ABCD
FNC1
E can not be read
ABCDE can not be read
Enable Disable Read only symbols without leading FNC 1.
Examples:
FNC1
ABCD
FNC1
E can not be read
A
FNC1
BCD
FNC1
E can not be read
FNC1FNC1
ABCD
FNC1
E can not be read
ABCD
FNC1
E will be read as ABCD
29
E
ABCDE will be read as ABCDE
Enable Enable Read both types of symbols.
Examples:
FNC1
ABCD
FNC1
E will be read as ABCD
29
E
A
FNC1
BCD
FNC1
E will be read as ABCD
29
E
FNC1FNC1
ABCD
FNC1
E will be read as ABCD
29
E
ABCD
FNC1
E will be read as ABCD
29
E
ABCDE will be read as ABCDE