Toshiba A100 Laptop User Manual


 
User’s Manual
6-2
P
OWER
AND
P
OWER
-
U
P
M
ODES
Table 1: Power conditions
Power on Power off (no operation)
AC
adaptor
connected
Battery fully
charged
•Operates
No charge
•LED: Battery Blue
DC IN Blue
No charge
•LED: Battery Blue
DC IN Blue
Battery
partially
charged or
no charge
•Operates
•Charge
•LED: Battery Amber
DC IN Blue
Quick charge
•LED:
Battery
Amber
DC IN Blue
No battery
installed
•Operates
No charge
•LED: Battery off
DC IN Blue
No charge
•LED: Battery off
DC IN Blue
AC
adaptor
not
connected
Battery
charge is
above low
battery
trigger point
•Operates
•LED: Battery off
DC IN off
Battery
charge is
below low
battery
trigger point
•Operates
•LED: Battery
flashes Amber
DC IN off
Battery
charge is
exhausted
Computer goes into
Hibernation or shuts down
(depending on the Toshiba
power Management Utility
Setting)
No battery
installed
No operation
•LED: Battery off
DC IN off