AS/400 Print Solution — Installation 37
Step 2: Setting up WorkStation Customization Object for TOSHIBA
e-STUDIO
This section describes how to set up the WorkStation Customization Object for
TOSHIBA e-STUDIO.
1. Login as a user with QSECOFR authority.
2. Execute the command below to add a library "WTEC02" to
the top of the library list.
ADDLIBLE WTEC02
3. Execute a command [TECSETQ] + [F4]. Then specify the
name of OUTQ (maximum 7 bytes) to be used, its library, the
IP address of the printer and default tray type*. Then press
the execution key.
* default tray type
- e-STUDIO5520C/6520C/6530C
Enter “ I ” (InnerTray) or “S” (SideTray). If you use both of them, enter one, set
up “WorkStation Customization Object for TOSHIBA e-STUDIO” and then set it
up again for registering the other.
- Other models
Enter “ I ” (InnerTray).
4. The setup is completed.
• The setup is properly completed unless any error messages appear.
• An error message appears when the specified OUTQ name already exists or
OUTQ was not generated because a parameter value is in error.
• If an error message appears or you stopped a command by pressing [F12] or
[F3], execute the command [TECSETQ] + [F4] again.