2. PRINTER SETUP ENGLISH VERSION EO1-33057
2.4 Loading the Media
E2- 8
2.4 Loading the Media
(Cont.)
The following procedures show how to adjust the position of the
movable sensor.
Feed Gap Sensor position adjustment
When using a label stock without black marks, the Feed Gap Sensor
is used to detect the print start position.
Looking inside of the Media Outlet, move the Movable Sensor by
rotating the Adjustment Knob until the Feed Gap Sensor aligns with
a gap. (T
he right side hole indicates the position of the Feed Gap
Sensor.)
Media Outlet
Adjustment
Knob
Left side hole:
Black Mark Senso
r
Right side hole:
Feed Gap Sensor
Forward Backward
NOTE:
A
djustment Knob
F
orward:
M
oves toward the centre
of the printer.
B
ackward: Moves away from the
centre of the printer.