Fast S
tart Times: When the port's LLDP state transforms from Disable (or R
x_Only)
to Tx&Rx (or Tx_Only), the fast start mechanism will be enabled,
that is, the transmit interval will be shorten to a second, and
several LLDPDUs will be sent out (the number of LLDPDUs
equals this parameter). The default value is 3.
13.1.2 Port Config
On this page you can configure all ports' LLDP parameters.
Choose the menu LLDPBasic ConfigPort Config to load the following page.
Figure 13-2 LLDP Port Config
The following entries are displayed on this screen:
LLDP Port Config
Port Select: Select the desired port to configure.
Admin S
tatus: Select the port’s LLDP operating mode:
Tx&Rx: send and receive LLDP frames.
Rx_Only: Only receive LLDP frames.
Tx_Only: Only send LLDP frames.
Disable: neither send nor
receive LLDP frames.
Notification Mode: Allows you to enable or disable the port
s' SNMP notification. If
enabled, the local device will notify the trap event to SNMP server.
Included TLVs: Select TLVs to be included in outgoing LLDPDU.
Det
ails: Click the Det
ail button to display the included TLVs and select the
desired TLVs.
150