Trango Broadband 5010 Network Router User Manual


 
Firmware Upgrade Procedure Example 1 Upgrade main image firmware to 1.0a6
Trango Broadband Wireless — Atlas5010 page 33
Example 1 Upgrade main image firmware to 1.0a6
FROM RADIO TELNET SESSION
Welcome to Trango Broadband Wireless, Atlas PtP-P5010M 3p0r1D07061901
Password:
Login as read/write.
#> tftpd on
Success.
#>
FROM COMPUTER COMMAND PROMPT SESSION
C:\Atlas>dir
Volume in drive C is Local Disk
Volume Serial Number is 7802-AAF7
Directory of C:\Atlas
06/28/2007 02:47 PM <DIR> .
06/28/2007 02:47 PM <DIR> ..
06/28/2007 02:47 PM 1,985,536 p5m_3p0r1D07062701_Pupgrade
06/28/2007 02:47 PM 131,584 web_1p1D05081601_Pupgrade
2 File(s) 1,999,872 bytes
2 Dir(s) 20,217,208,832 bytes free
C:\Atlas>tftp -i 10.254.1.2 put p5m_3p0r1D07062701_Pupgrade
Transfer successful: 1868288 bytes in 9 seconds, 207587 bytes/s
C:\Atlas>
NOTE: AT THIS POINT WAIT THREE MINUTES BEFORE PROCEEDING
Example 2 Upgrade web firmware to 1.1
FROM RADIO TELNET SESSION
Welcome to Trango Broadband Wireless, Atlas PtP-P5010M 3p0r1D07061901
Password:
Login as read/write.
#> tftpd on
Success.
#>
FROM COMPUTER COMMAND PROMPT SESSION
C:\Atlas>tftp -i 10.254.1.2 put web_1p1D05081601_Pupgrade
Transfer successful: 131584 bytes in 1 second, 131584 bytes/s
C:\Atlas>