Transition Networks SISPM1040-182D Switch User Manual


 
Transition Networks SISPM1040-182D-LR
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
116
a certain period (for details, see the IEEE 802.3af specification).
Capacitive Detection: If the port and capacitive detection are enabled, the
capacitances state reads in the voltage result from the constant current. This is then
subtracted from the pre-capacitance voltage to get a charge rate. If this charge rate
is within the window of the PD signatures, the device is considered to be discovered.
Start: Showing with a tick symbol, the system initializes and resets successfully.
And then, click
Apply
to carry into effect.
Port: The index of PoE ports.
Enable State: Check it to enable the PoE function to the port.
Power Limit From: Check it to decide the power limit method.
¾
Classification
: When this check box is ticked, the system will limit the power
supply to the powered device in accordance with the related class.
Legacy:
Check it to support the legacy power devices.
Priority:
Pull down the selection menu item to choose the priority of power
supplying.
Port Limit (<15400) mW:
User can key in the power limit value which is under 15.4
Watts.
Mode:
Displays the operating mode of the port.
Current (mA):
Displays the operating current of the port.
Voltage (V):
Displays the operating voltage of the port.
Power (mW):
Displays the power consumption of the port.
Determined Class:
Displays the PD’s class.
And then, click
Apply