Transition Networks SISPM1040-182D Switch User Manual


 
Transition Networks SISPM1040-182D
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
6.8.3 System Event Log—Event Configuration
Having ticked the
Syslog
/
SMTP
checkboxes, the event log/email alert will be sent to the
system log server and the SMTP server respectively. Also, Port event log/alert (link up,
link down, and both) can be sent to the system log server/SMTP server respectively by
setting the trigger condition.
System event selection: There are 4 event types—Device Cold Start, Device
Warm Start, Authentication Failure, and X-ring Topology Change. The checkboxes
are not available for ticking unless the Syslog Client Mode on the Syslog
Configuration tab and the E-mail Alert on the SMTP Configuration tab are enabled
first.
¾ Device cold start: When the device executes cold start action, the system will
issue the event log/email alert to the system log/SMTP server respectively.
¾ Device warm start: When the device executes warm start, the system will
issue the event log/email alert to the system log/SMTP server respectively.
¾ Authentication Failure: When the SNMP authentication fails, the system will
issue the event log/email alert to the system log/SMTP server respectively.
¾ X-ring topology change: When the X-ring topology has changed, the system
will issue the event log/email alert to the system log/SMTP server respectively.
Port event selection: Also, before the drop-down menu items are available, the
Syslog Client Mode selection item on the Syslog Configuration tab and the E-mail
Alert selection item on the SMTP Configuration tab must be enabled first. Those
drop-down menu items have 3 selections—Link UP, Link Down, and Link UP &
Link Down. Disable means no event will be sent to the system log/SMTP server.
¾ Link UP: The system will only issue a log message when the link-up event of
the port occurs.
¾ Link Down: The system will only issue a log message when the link-down
event of port occurs.
¾ Link UP & Link Down: The system will issue a log message at the time when
port connection is link-up and link-down.