Transition Networks SISTF10XX-140-LR(T) Switch User Manual


 
14
SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T)
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Cable Specifications -- Continued
Copper Cable
Category 5: (minimum requirement)
Gauge / Attenuation: 24 to 22 AWG / 22.0 dB per 100m @ 100 MHz
• Straight-through OR crossover cable may be used.
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Crossover Cable
1
2
3
6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1
2
3
6
1
2
3
6
1
2
3
6
15
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Technical Specifications
For use with Transition Networks Model Ethernet switch or equivalent
Standards: IEEE 802.3™, 802.3u™; 802.3x™
Data Rate: 10 Mb/s, 100 Mb/s (copper); 100 Mb/s (fiber)
Processing Type: Store and Forward
w/ IEEE802.3x™ full-duplex, non-blocking flow control
Dimensions: 1.8" x 5.3" x 4.1" (46 mm x 135 mm x 105 mm)
Weight: 1.4 lb. (0.63 kg) (approximate)
Input Voltage: 12-48VDC, 0.2-0.7A, 2.4W (minimum), (redundant inputs)
Input Current: 0.25 A @ 24 VDC (SISTF10xx-140-LR(T))
0.35 A @ 24 VDC (SISTF10xx-160-LR(T) / -170-LR(T))
Overload Current: 1.1 A (SISTF10xx-140-LR(T))
1.6 A (SISTF10xx-160-LR(T) / -170-LR(T))
reverse polarity protection on all models
Forward & Filtering: 148810 pps
Packet Buffer: 256 KB
Address Table Size: 1000 Unicast MAC addresses
Latency: < 5 µs
Alarm Relay: 1.0 A @ 24 VDC
Mechanical: Ingress Protection: IP30
Environment: Tmra* (standard temp): 0 to 60°C (32 to 140°F)
Tmra* (extended temp): -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 5 to 95%, non condensing
Warranty: Lifetime
*Manufacturer’s rated ambient temperature.
The information contained in this user’s guide is subject to change. For the most
up-to-date information see the user’s guide on line at: www.transition.com.
CAUTION: This device is intended to be supplied by a listed power unit
marked LPS or Limited Power Source, provided with a connector for field
wiring terminal, and output rated 12-48VDC, 0.2-0.7 A, 24 W minimum.
CAUTION: This device is designed for operation with a safety extra-low
voltage (SELV) in compliance with IEC950 / EN60950 / VDE0805 and in
compliance with the low voltage directive 73/23/EEC and 93/68/EEC.