Uniden UBC780XLT Scanner User Manual


 
31
Service Search
The Service Search feature allows you to toggle through the following five preprogrammed
services. The frequencies selected for these services are the most commonly used around
the Australia.
1: POLICE
2: RAILROAD
3: AIR
4: MARINE
5: UHF CB
1.Press SVCthe display indicates
as illustrated.
2.After a 3 second delay, searching begins for the first
preprogrammed service – Police (initial setting).
3.If you want to skip a frequency, press SRCHto start searching immediately.
4.To change the searched service, use , or VFOafter pressing SVC.
Note:You can not change such settings as delay, during a service search.
• The channel number corresponding to certain services will appear when a
frequency within the search is active.
You can enter one of the Service Search frequencies into Channel Memory by
pressing Ewhen holding on one of the frequencies.
5. To exit from the service search mode, press MANor SCAN.
During the search of one of the preprogrammed services, the lower display line will indicate
the service that you are searching. To stop the search, press HOLD/.
HOLDappears in the
display. Press HOLD/or LIMIT/to move up or down one programmed frequency, or press
SRCHto resume scanning.
Service Search Skip
You can set the scanner to skip the frequencies unwanted during service search. 100
skipped frequencies are programmable.
1.To skip over a frequency, press L/Owhen stopping at the frequency you want to skip.
2.To cancel a skip during search, press HOLD/,
tune in the desired frequency using , or VFO,
then press L/O.
To restore all skipped frequencies, pressL/Ofor 2 seconds.
1
:
POLICE
2
:
RAILROAD
SERVICE SEARCH
POLICE
ADDENDUM SHEET