Vidikron 90 Projector User Manual


 
Specifications
7-2 Vidikron Vision Model 90 Owner’s Operating Manual
Brightness and Contrast: Cinema Standards Measurement System (CSMS)
Specifications
- Brightness: 45.3 foot-Lamberts (fL)
- Contrast Ratio: 258:1
These measurements are taken from the projector in a controlled,
home theater environment. All measurements are made to
ANSI/NAPM IT7.228-1997 specifications using the Photo Research
PR-650 SpectraColorimeter and Minolta LS-100 Luminance Meter,
Video Essentials test DVD and a 1.3 gain, 72-inch wide screen. The
projector is calibrated to a color temperature of 6,500K and has a
minimum of 150 hours of usage.
The foot-Lambert (fL) is the unit of measurement used in commercial
movie theaters to express image brightness at the screen surface.
The Society of Motion Picture and Television Engineers (SMPTE)
specifies 16 fL as the target image brightness for film-based
projectors using an open gate (without film in the projector). More
importantly, today SMPTE specifies 12 fL as the target image
brightness in Digital Cinema theaters. The foot-Lambert
measurement is dependent on screen size, screen gain and projector
light output.
Home Theater Calibration Specifications
- Light Output: 1120 ANSI Lumens
- Contrast Ratio: 258:1
These specifications are obtained by calibrating the projector as
described above for CSMS measurements.
Industry-Standard Specifications
- Light Output: 2250 ANSI Lumens
- Contrast Ratio: 3000:1
These are typical projector brightness and contrast specifications
found in most companies’ sales literature. Vidikron includes these
measurements in its literature to allow for direct comparison with
other manufacturers’ projectors. These measurements are typically
taken at 9,000K to 13,000K to get expected performance data when
the projector is used in professional, commercial and industrial
displays.
Lamp: 275W UHP
Estimated Lamp Life: 2000 hours
Inputs: (1) Composite; (2) S-Video; (1) Component; (2) HD-R (Pr), G
(Y), B (Pb), H, V; (2) DVI w/HDCP
Control Options: •Built-in keypad
Discrete infrared remote
Serial commands via RS-232
Trigger Outputs: 3 x 12 VDC, 800 mA
Bandwidth: 150 Mega Samples/Second (MSPS)
Power Requirements: 100 to 240 VAC (auto-sensing), 50/60 Hz, 610 Watts
Operating Environment: 41°F to 95°F (5°C to 35°C), 0% to 90% humidity
(non-condensing)
Dimensions: See Figure 7-1
Weight (without lens): 65 lbs. (29.48 kg)