Vidikron VL-52 Computer Monitor User Manual


 
Operation
30 Vidikron VL-52 and VL-57 Owner’s Operating Manual
PRE
L
IMINAR
Y
PLUGE patterns vary but generally consist of some combination of black, white and gray
areas against a black background. The example above includes two vertical bars and four
shaded boxes.
Select Brightness from the Picture Adjust menu. Using the left- and right-arrow ( )
buttons, adjust the brightness so that:
The darkest black bars disappear into the background.
The dark gray areas are barely visible.
The lighter gray areas are clearly visible.
The white areas are a comfortable level of true white.
The image contains only black, gray and white (no color).
Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the
one shown in
Figure 4-3.
Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast
Select Contrast from the Picture Adjust menu. Using the left- and right-arrow ( )
buttons, adjust the contrast to a point just below which the white rectangle starts to increase
in size.
Brightness and contrast controls are interactive. A change to one may
require a subtle change to the other in order to achieve the optimum
setting.
Note