Vidikron VP-50 Computer Monitor User Manual


 
88
16 BLUE GAIN DATA
Function
The external control equipment changes the BLUE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: BLUE Gain Flag 03H
DATA02: BLUE Gain 1 (Offset) D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
DATA03 BLUE Gain 2 (Drive) D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: BLUE Gain Flag 03H
17 VID NR MODE SET
Function
The external control equipment sets the VID NR (Noise Reduction) mode of the plasma
monitor.
Transmission Data
DFH 80H 60H C0H 01H DATA00 CKS
DATA00: 01H: VID NR OFF
02H: VID NR-1
03H: VID NR-2
04H: VID NR-3
ACK
7FH 60H 80H C0H 01H DATA00 CKS
DATA00: 01H: VID NR OFF
02H: VID NR-1
03H: VID NR-2
04H: VID NR-3
External Controls