Performing Calibration
Note: This step is very important and must always be carried out whenever
media is being changed. Failure to do so will result in mis-detection of
the label size.
1. Press and hold the feed button while turning on the power until the printing
motor becomes activated.
2. The calibration is complete when the printer automatically feeds the
label stock.
3. Press feed button one more time to line label up for printing.
Printing Configuration Report
1. Press and hold the feed button while turning on the power.
2. Continue holding down the feed button.The printer will begin to feed
approximately 12” of blank media. The printer will then print a configuration
report.This report states the firmware version, ROM checksum, RS232,
thermal transfer/direct thermal settings, hardware configuration and font types.