Status Registers
Overview
72 Operating Manual for Multichannel Functionality (GPIB-M)
Table 4.1 OPERation Status Register
REGulating
Sub-Register
This describes the regulating mode. If none of these bits is active, the output
unregulated (UNRegulated) bit is active in the questionable status register.
Table 4.2 REGulating Sub-Register
Bit Bit Weight Bit Name Description
0 1 CALibrating Indicates that the supply is in
CALibration Mode.
1 2 Reserved Not implemented
2 4 Reserved Not implemented
3 8 Reserved Not implemented
4 16 Reserved Not implemented
5 32 Waiting for TRIGger
Summary
Indicates if the supply is waiting
for a TRIGger.
6 64 Reserved Not implemented
7 128 Reserved Not implemented
8 256 REGulating Summary Reflects the summary of the
REGulating Sub-Register.
9 512 SHUTdown Summary Reflects the summary of the
SHUTdown Sub-Register.
10 1024 Remote CONtrol
Summary
Reflects the summary of the
Remote CONtrol Sub-Register.
11 2048 Current SHareSummary Reflects the summary of the
Current Share Sub-Register.
12 4096 Not Used Not used
13 8192 Reserved Not implemented
14 16384 PROGram Running Indicates that an Automated
Sequence is running.
15 32768 Not Used Not used
Bit Bit Weight Bit Name Description
0 1 CV The power supply is regulating in Constant
Voltage mode.
1 2 CC The power supply is regulating in Constant
Current mode.