Ethernet (ENET)
2-26 M370078-06
Advanced Section
The advanced section describes the setup and connection for various
network topologies involving multiple power supplies.
Network Topology 1: Simple LAN
The simple LAN topology is the most common configuration for setting
up the ENET option on the XG. The topology follows the typical star
topology provided by a HUB and multiple XGs with the ENET option
and one or more computers. Figure 2-30 shows this configuration.
All devices connects via the HUB. Every device must have a unique IP
address, for example:
Computer #1: 169.254.117.231
Computer #2: 169.254.117.232
Power supply #1: 169.254.117.220
Power supply #2: 169.254.117.221
Power supply #3: 169.254.117.222
Power supply #30: 169.254.117.230.
You must set up every device manually.
Figure 2-30
Multiple Power Supplies and Two Computers
Local Computer #1 Local Computer #2
ENET
ENET
ENET
Power Supply #1
Power Supply #30
Power Supply #2
HUB