Xantrex Technology RS232-HPD Power Supply User Manual


 
Features and Specifications
Specifications
14 Operating Manual for RS-232 for XT/HPD Series Power Supply
Table 1.2 Specifications for HPD 300 W Series Supply with RS-232 Interface Installed
Models 15-20 30-10 60-5
Program Resolution
Voltage
Current
OVP
2.4mV
2.8mA
2.4mV
4.7mV
1.4mA
4.7mV
9.3mV
0.7mA
9.3mV
Program Accuracy
1
Voltage
Current
OVP
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model HPD 15-20 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 20mV ± 0.1% of the set voltage of
10 volts.
60mV
±0.1%
75mA
±0.12%
150mV
70mV
±0.1%
50mA
±0.12%
300mV
90mV
±0.12%
25mA
±0.1%
600mV
Readback Resolution
Voltage
Current
2.4mV
2.8mA
4.7mV
1.4mA
9.3mV
0.7mA
Readback Accuracy
1
Voltage
Current
45mV
±0.3%
75mA
±0.12%
90mV
±0.3%
40mA
±0.12%
175mV
±0.3%
25mA