Auxiliary connector J7, located on the RS-232 interface rear panel, provides
several signals to increase your operating control of the supply. These signals are
dependent on the operator's design and uses. The operation of the J7 signal requires
that you provide external Vcc and ground. Use a standard 8-position RJ45
connector and data cable to connect to J7. To locate the connector, refer to the
RS-232 interface subplate drawing in Figure 2.2, on page 16. See Figure 2.5 for pin
descriptions. The J7 outputs can sink a current of 5mA each. Figure 2.6, on page
32 shows the portion of the option board schematic which contains the J7
connector. Use the schematic as a reference when making input or output
connections.
Figure 2.5 User Signals J7 Connector
J7-1 External TTL shutdown input signal
(See “TTL Shutdown”)
J7-2 Polarity signal, open collector
(asserted by VSET -x)
J7-3 Isolation signal, open collector
(asserted by OUT OFF)
J7-4 Fault signal, open collector
(asserted when bit set in fault register)
J7-5 External Vcc, 15V maximum
(supplied by connecting and operating an external source)
J7-6 External ground and shutdown return
(supplied by connecting and operating an external source)
J7-7 Open collector user signal
(asserted by AUXA ON)
J7-8 Open collector user signal
(asserted by AUXB ON)