Power Supply Operation
68 Operating Manual for XDC Series Power Supply
These 2 extra steps are shown in the following example.
To set the Under-Voltage Protection:
To set the Over-Current Protection:
Step # Do This You Will See
1 OVP SET 0V
2 Press repeatedly until the
desired setting appears.
UVP SET 0V
3 UVP SET 0V
4
Use the Voltage knob, the numeric
keypad, or the arrow keys to enter a
value (0–103% of the unit’s rated
voltage).
UVP SET ####V
5 S/D if trip? N
6 Use the arrow keys to select Yes or
No. For this example, Yes is selected.
S/D if trip? Y
7 This setting is saved and the display
returns to its default operating mode.
Step # Do This You Will See
1 OVP SET 0V
2 Press repeatedly until the
desired setting appears.
OCP SET 0A
3 OCP SET 0A
4
Use the Current knob, the numeric
keypad, or the arrow keys to enter a
value (0–103% of the unit’s rated
current).
OCP SET ####A
5 S/D if trip? N
6 Use the arrow keys to select Yes or
No. For this example, Yes is selected.
S/D if trip? Y
7 This setting is saved and the display
returns to its default operating mode.
PROT SET
ALARMS
PROT SET
ALARMS
ENTER
ENTER
ENTER
PROT SET
ALARMS
PROT SET
ALARMS
ENTER
ENTER
ENTER