Xantrex Technology XDC Power Supply User Manual


 
Operation
Power Supply Operation
Release 3.0 83
Configure
User Lines
The USER LINES menu option lets you configure the auxiliary status lines
The Auxiliary (Aux) lines are 2 open collector outputs that can be used to monitor
the status of the power supply. The auxiliary lines are referred to as AUX A and
AUX B. See “Making Connections for Remote Control” on page 107 for details.
Each user line also has a corresponding annunciator on the front panel display to
indicate when it is on. Aux lines can be set up to report the following status
conditions:
None
Unregul: Output Unregulated
OVP: Over-Voltage Condition
UV: Under-Voltage Condition
OC: Over-Current Condition
UC: Under-Current Condition
OP: Over-Power Condition
UP: Under-Power Condition
AC Off: Input power has failed or is out of range
OTP: Over-Temperature Condition
Hi Temp: High-Temperature Condition
SenseProt: Sense Protection Tripped
Fold Prot: Fold Protection Tripped
CC: Constant Current Mode
CV: Constant Voltage Mode
CP: Constant Power Mode
Out ON: Output On
Out OFF: Output Off
To access and work with the USER LINES menu option:
Step # Do This You Will See
1 ERROR MSGS
2
1
1. You can also press MENU again to bring up the AUX LINES option.
USER LINES
3 Aux line A
4 or to select which
line to configure.
Aux line B
5
Cfg None
MENU
ENTER
ENTER