ZyXEL Communications 310 Network Router User Manual


 
Prestige 310 Broadband Sharing Gateway
5-6 Remote Node Setup
5.2 Editing TCP/IP Options (with Ethernet Encapsulation)
Move the cursor to the Edit IP field in Menu 11.1, then press the [SPACE BAR] to toggle and set the value
to Yes. Press [Enter]
to open Menu 11.3 - Network Layer Options.
Figure 5-4 Remote Node Network Layer Options
The next table gives you instructions about configuring remote node network layer options.
Table 5-4 Remote Node Network Layer Options Menu Fields
Field Description Example
IP Address
Assignment
If your ISP did not assign you an explicit IP address, select Dynamic;
otherwise select Static and enter the IP address & subnet mask in
the following fields.
Dynamic
IP Address If you have a Static IP Assignment, enter the IP address assigned to
you by your ISP.
IP Subnet
Mask
If you have a Static IP Assignment, enter the subnet mask assigned
to you.
Gateway IP
Addr
If you have a Static IP Assignment, enter the gateway IP address
assigned to you.
Single User
Account
Use the [SPACE BAR] to choose Yes or No. Yes
Metric This field is valid only for PPTP/ PPPoE encapsulation. The metric
represents the “cost” of transmission for routing purposes. IP routing
uses hop count as the measurement of cost, with a minimum of 1 for
directly connected networks. Enter a number that approximates the
cost for this link. The number need not be precise, but it must be
3
Menu 11.3 - Remote Node Network Layer Options
IP Address Assignment= Dynamic
IP Address= N/A
IP Subnet Mask= N/A
Gateway IP Addr= N/A
Single User Account= Yes
Metric= N/A
Private= N/A
RIP Direction= None
Version= N/A
Multicast= None
Enter here to CONFIRM or ESC to CANCEL:
Press Space Bar to Toggle.