ZyXEL Communications VES-1616F-3X Switch User Manual


 
Chapter 32 Introducing the Commands
VES-1616F-3x Series User’s Guide
240
32.11.8 vlan Commands
The following table lists the vlan commands in configuration mode.
us <1|2> Sets a rate adaptive mode for the
upstream traffic
1: Manual
2: AdaptAtInit
13
rateratio ds <0..100> Specify the downstream data rate
allocated for the fast and slow
channels.
0: slow channel
100: fast channel
13
us <0..100> Specify the upstream data rate
allocated for the fast and slow
channels.
0: slow channel
100: fast channel
13
snr dsmax <0..127> Sets the maximum downstream
SNR (Signal to Noise Ratio).
13
dsmin <0..127> Sets the minimum downstream
SNR (Signal to Noise Ratio).
13
dstarget
<0..127>
Sets the target downstream SNR
(Signal to Noise Ratio).
13
usmax <0..127> Sets the maximum upstream
SNR (Signal to Noise Ratio).
13
usmin <0..127> Sets the minimum upstream SNR
(Signal to Noise Ratio).
13
ustarget
<0..127>
Sets the target upstream SNR
(Signal to Noise Ratio).
13
targetslowburst ds <0..1275> Sets the target burst rate for the
downstream slow channel.
13
us <0..1275> Sets the target burst rate for the
upstream slow channel.
13
Table 85 vdsl-profile Commands (continued)
COMMAND DESCRIPTION P
Table 86 vlan Commands
COMMAND DESCRIPTION P
vlan <1-4094> Creates a new VLAN group. 13
exit Leaves the VLAN configuration mode. 13
fixed <port-
list>
Specifies the port(s) to be a permanent
member of this VLAN group.
13
forbidden
<port-list>
Specifies the port(s) you want to prohibit from
joining this VLAN group.
13
help Displays a list of available VLAN commands. 13
inactive Disables the specified VLAN. 13
ip address <ip-address>
<mask>
Sets the IP address and subnet mask of the
switch in the specified VLAN for packet
loopback test.
13