1.7.8 Fan Access Panel
The Fan Access Panel, shown in Figure 15, has a hinged front panel that swings down providing
access to the two fans cooling the RAN chassis. These fans are user-replaceable. This panel has
labels identifying the electronic modules located in the cPCI shelf below the panel.
Figure 15. Fan Access Panel
1.7.9 800 MHz Multicoupler (C/MCPLR)
The 800 MHz (C/MCPLR) Module is a cPCI electronic module that houses the dual-diversity,
receive unit for the 800 MHz bands. This module interfaces to the multiplexer system and
contains the front end low noise amplifiers for the reverse path. The module has six outputs
(Cell bands A, B, and 800 MHz, with diversity).
Figure 16 shows the location of the faceplate components. Table 10 describes the faceplate
components.
5 PA CNTL 2/4 I2C flatpack
connector
PA Control Channel 2 or 4. Outputs control data to the PIC card
on the PAA for the channel being provided (using cable
1955000P079)*
6 FLT Red LED Fault. Turns red when the module has failed. Indicator is lit dur-
ing start-up until module has initialized. Indicator will blink
after module receives system clock and is awaiting initialization
7 PWR Green LED Power. Turns green when module has power
8 CH 2/4 OUT SMA connector Channel 2 or 4 OUT*
Table 9. RAN Up Converter Module Faceplate Components
REF # DESIGNATION DEVICE FUNCTIONAL DESCRIPTION
21318-A
LABELS FOR CPCI
ELECTRONIC MODULES