Crestron C2N-SPWS300 System Power Supply
Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 23
Firmware Upgrade
A firmware upgrade file has the
extension .csf.
To take advantage of all the C2N-SPWS300 features, it is important that the unit
contains the latest firmware available. Therefore, please check the Crestron website
(http://www.crestron.com/downloads/software_updates.asp) for the latest version of
firmware. Not every product has a firmware upgrade, but as Crestron improves
functions, adds new features, and extends the capabilities of its products, firmware
upgrades are posted. To upgrade the firmware, complete the following steps.
1. Make sure that “Communication Settings” that begins on page 19 has
been performed.
2. As shown after this step, select File Transfer | Load Network Device
from the Viewport menu.
File Transfer | Load Network Device Command
3. As shown after this step, select the NET ID of the C2N-SPWS300 and
then click OK. The “Open” window appears (refer to the subsequent
graphic).
“Select Network ID” Window
NOTE: When transferring any Cresnet file (touchpanel project/firmware), lower the
port speed baud rate to 38400 to match the Cresnet bus speed.