C2N-SPWS300 Physical Views
12.75 in
(32.39 cm)
13.25 in
(33.66 cm)
3.29 in
(8.36 cm)
5.19 in
(13.18 cm)
4.00 in
(10.16 cm)
3.00 in
(7.62 cm)
Each power supply channel (1 through 8) has a green LED (PWR), which
illuminates when 24V is present at that output. A red LED (OVLD) for each channel
illuminates when there has been a short circuit or the load exceeds the nominal 75
watts for any channel.
A system-wide red LED (OVLD) illuminates when the full 300 watts (12.5 amps) of
the C2N-SPWS300 is exceeded.
Pushbuttons
A pushbutton (RESET) associated with each channel allows the user to reset the
circuit breaker for each channel and turn on that channel. Power is restored to an
overloaded channel if the excess load has been removed from the channel or the
channel was set into overload because of a system overload caused by another
channel.
A system-wide pushbutton (RESET) is available to reset all eight-channel circuit
breakers and turn on all channels assuming excessive loads have been removed.