A SERVICE OF

logo

IPL T CR48 • Communication and Control
4-15
Command ASCII (Telnet) URL Encoded (Web) Response
Relay functions
Pulse relay
1*3*
X6#
O
X!
%2A3%2A
X6#
O Cpn
X!
• Rly3
]
Toggle relay
X!
*2O
X!
%2A2O Cpn
X!
• Rly2
]
Turn relay ON
X!
*1O
X!
%2A1O Cpn
X!
• Rly1
]
Turn relay OFF
X!
*0O
X!
%2A0O Cpn
X!
• Rly0
]
View relay status
X!
O
X!
O
X%]
Input Contact Closure port
View the input state or
value
X!
]
X!
%D+
X4#]
Firmware Version/Part Number/Information
Query rmware version Q Q
X1!]
Query verbose version
information
0Q 0Q sum of responses from 2Q-
3Q-4Q
]
Query rmware version 1Q 1Q
X1!]
Query bootstrap version 2Q 2Q
X1!]
N
X! = Specic port number (01-99)
X% = On/off status: 0 = off/disable; 1 = on/enable
X1! = Unit version number
X4#
= Input state: 0 = off; 1 = on
X6# = Pulse time in 20 ms per count. If parameter is missing or = 0, pulse length = default (25 counts = 500 ms), max
(65536 counts)