20
Operational State field Displays the general condition of the interface card. The general
condition may appear as any of the following:
unknown
normal
wrong-image
bootFailed
tooHot
booting
A condition of unknown indicates an unsupported interface
card. To address this condition, replace the card with a
supported card.
The operational state of a card must appear as normal for the
current status of the card to appear as up.
A wrong-image condition indicates that the active system
image on the interface card does not match the active system
image on the controller. All cards must run the same active
system image as the controller card to function.
A bootFailed condition indicates that the active system image
on the card was incompletely or incorrectly loaded. If the other
interface cards come up successfully, reset the individual card.
Otherwise, reboot your entire device.
When your card overheats, the tooHot condition appears in the
show card command output. Enter the
show fan
command to
check to see if your fans failed.
The booting condition indicates that the card has not finished
loading necessary image data for internal configuration.
Boot Stage field Boot Stage appears as one of the following:
recovery
ipl
ppcboot
fpga
•pic
•ib
rootfs
•kernel
•exe
done
none
Table 3-2: Card Properties Window Elements (Continued)
Element Description