A SERVICE OF

logo

CDM-Qx Satellite Modem Revision 5
Front Panel Operation MN/CDMQx.IOM
5–58
If the measured values are greater than, or equal to 16.0 dB, the display will show
16.0 dB. If AUPC is not enabled, the values of maximum and average TPLI will both
show ‘Off'.
Examples:
08.0, 13.5, 2.5, 1.8 means:
Minimum Eb/No observed in the measurement interval = 8.0 dB
Average Eb/No observed in the measurement interval = 13.5 dB
Maximum TPLI observed in the measurement interval = 2.5 dB
Average TPLI observed in the measurement interval = 1.8 dB
Loss, 04.5, Off, Off means:
There was a loss of demod lock during the measurement interval
Average Eb/No observed in the measurement interval = 4.5 dB
Maximum TPLI observed in the measurement interval = AUPC disabled
Average TPLI observed in the measurement interval = AUPC disabled
If the user selects Config, the following sub-menu is displayed:
(MonitorStatsClear-All) – CLEAR ALL STATS
If the user selects Clear-All, the statistics log is cleared, and the user is taken directly
back to the previous menu.
If the user selects Config, the following sub-menu is displayed:
(MonitorStatsConfig) – CONFIGURE STATS
The user is prompted to enter the logging interval (the period of time over which the
statistics will be measured), using the STarrow keys, then press ENT. The user can
choose Disabled, 10, 20, 30, 40, 50, 60, 70, 80, or 90 minutes.
Stats Logging Interval:
Disabled (▲▼,ENT)
Stats Logging Interval:
30 minutes ( ENT)
Clear all Stored Stats?
No Yes (▲▼,ENT)