CDM-Qx Satellite Modem Revision 4
Remote Control MN/CDMQx.IOM
C-43
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command or
Response to
Query
Description of arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
BUC Output
Enable
(L-Band Unit
only)
BOE= 1 byte, value
of 0,1
Command or Query
Indicates BUC Output enable
0=Off (Output Disabled)
1=On(Output Enabled)
Example: BOE=1 (BUC Output is Enabled)
Note: This command is only valid when the BUC FSK comms
and BUC power are enabled.
BOE=
BOE?
BOE*
BOE#
BOE^
BOE? BOE=x
(see description of
arguments)
BUC High
Current Limit
(L-Band Unit
only)
BCH= 4 bytes Command or Query
BUC High Current Limit, a value between 500 and 3200 mA
Example: BCH=3100
BCH=
BCH?
BCH*
BCH#
BCH^
BCH? BCH=xxxx
(see description of
arguments)
BUC Low
Current Limit
(L-Band Unit
only)
BCL= 4 bytes Command or Query
BUC Low Current Limit, a value between 100 and 3000 mA
Example: BCL=0600
BCL=
BCL?
BCL*
BCL#
BCL^
BCL? BCL=xxxx
(see description of
arguments)
BUC LO
Frequency
(L-Band Unit
only)
BLO= 6 bytes Command or Query
BUC transmit LO frequency information in the form: xxxxxs,
where :
xxxxx is the LO frequency in the range of 3000 to 65000 MHz
All 0’s (000000) disables the feature
S is the sign for the mix (+ or – character)
Terminal Frequency= BUC LO TFQ
Example: BLO=12000+ (BUC LO is 12 GHz, low-side mix)
BLO=
BLO?
BLO*
BLO#
BLO^
BLO? BLO=xxxxxs
(see description of
arguments)
BUC Output
Power Level
(L-Band Unit
only)
N/A 4 bytes Query only
BUC output power level in the form xxx, where xxx is the value
in watts.
Example: BOL=08.3 (BUC reports output is 8.3 watts)
Returns 00.0 when FSK and BUC power are not enabled.
N/A BOL? BOL=xx.x
(see description of
arguments)