3Com 8810 Switch User Manual


 
Powering and Booting the Switch 75
Verifying after Power-on
(Recommended)
To ensure the configuration works that you will make on the switch, you are
recommended to check the switch after powering it on to make sure that:
The cooling system is working. In this case, you can hear the noise caused by
fan rotation and feel that there is air exhausted out.
All the system LEDs on the fabrics function normal.
Boot Interface The Switch 8807 is used as an example in this section.
The following is the information that will be output at the Console terminal when
you power on the switch.
ZBB_TEST
Starting...
******************************************
* *
* 3Com Switch 8800 Family Bootrom, Version 106 *
* *
******************************************
Copyright(C) 2001-2005 by 3Com CORPORATION
Creation date: Jun 6 2003, 19:28:01
CPU type : MPC755
CPU L2 Cache : 1024KB
CPU Clock Speed : 400MHz
BUS Clock Speed : 100MHz
Memory Size : 512MB
Flash file system init....done
Switch 8800 Family 3C17508 board self testing.....................
The board is steady
SlotNo of this 3C17508 is 0
BootRom main system CRC check is OK
82559 register testing is OK
EPLD1 testing is OK
EPLD2 testing is OK
16c2552 register testing is OK
Please check LEDs......................LED testing finished
The switch Mac address is 00e0.fc00.00a1
Press Ctrl+B to enter Boot Menu... 0
Auto-booting...
Booting from Flash...
Decompress Image...................................................
.......................................................OK!
Starting at 0x10000...
User interface Con 0 is available
Press ENTER to get started.
The above prompt information appears when the switch completes its boot
sequence. Press Enter to begin configuring the switch.
n
The Switch 8800 Family provide abundant command views. For more information
about the configuration commands and the Command Line Interface (CLI), see
3Com Switch 8800 Family Routing Switches Operation Manual.