Accton Technology ES4512C Switch User Manual


 
Command Line Interface
4-50
4
Command Usage
The specified level indicates an event threshold. All events at this level or
higher will be sent to the configured email recipients. (For example, using
Level 7 will report all events from level 7 to level 0.)
Example
This example will send email alerts for system errors from level 3 through 0.
logging sendmail source-email
This command sets the email address used for the “From” field in alert messages.
Syntax
logging sendmail source-email email-address
email-address - The source email address used in alert messages.
(Range: 1-41 characters)
Default Setting
None
Command Mode
Global Configuration
Command Usage
You may use a symbolic email address that identifies the switch, or the
address of an administrator responsible for the switch.
Example
This example will send email alerts for system errors from level 3 through 0.
logging sendmail destination-email
This command specifies the email recipients of alert messages. Use the no form to
remove a recipient.
Syntax
[no] logging sendmail destination-email email-address
email-address - The source email address used in alert messages.
(Range: 1-41 characters)
Default Setting
None
Command Mode
Global Configuration
Console(config)#logging sendmail level 3
Console(config)#
Console(config)#logging sendmail source-email bill@this-company.com
Console(config)#