Accton Technology ES4548C Switch User Manual


 
Command Line Interface
4-16
4
Example
To set the silent time to 60 seconds, enter this command:
Related Commands
password-thresh (4-15)
databits
This command sets the number of data bits per character that are interpreted and
generated by the console port. Use the no form to restore the default value.
Syntax
databits {7 | 8}
no databits
7 - Seven data bits per character.
8 - Eight data bits per character.
Default Setting
8 data bits per character
Command Mode
Line Configuration
Command Usage
The databits command can be used to mask the high bit on input from
devices that generate 7 data bits with parity. If parity is being generated,
specify 7 data bits per character. If no parity is required, specify 8 data bits per
character.
Example
To specify 7 data bits, enter this command:
Related Commands
parity (4-17)
Console(config-line)#silent-time 60
Console(config-line)#
Console(config-line)#databits 7
Console(config-line)#