Accton Technology ES4548C Switch User Manual


 
Configuring the Switch
3-20
3
RAM Level – Limits log messages saved to the switch’s temporary RAM memory
for all levels up to the specified level. For example, if level 7 is specified, all
messages from level 0 to level 7 will be logged to RAM. (Range: 0-7, Default: 7)
Note:
The Flash Level must be equal to or less than the RAM Level.
Web – Click System, Logs, System Logs. Specify System Log Status, set
the level of
event messages to be logged to RAM and flash memory, then click Apply.
Figure 3-12. System Logs
CLI – Enable system logging and then specify the level of messages to be logged to
RAM and flash memory. Use the show logging command to display the current
settings.
Remote Log Configuration
The Remote Logs page allows you to configure the logging of messages that are
sent to syslog servers or other management stations. You can also limit the event
messages sent to only those messages at or above a specified level.
Command Attributes
Remote Log Status – Enables/disables the logging of debug or error messages
to the remote logging process. (Default: Disabled)
Logging Facility – Sets the facility type for remote logging of syslog messages.
There are eight facility types specified by values of 16 to 23. The facility type is
used by the syslog server to dispatch log messages to an appropriate service.
The attribute specifies the facility type tag sent in syslog messages. (See RFC
3164.) This type has no effect on the kind of messages reported by the switch.
However, it may be used by the syslog server to process messages, such as
sorting or storing messages in the corresponding database. (Range: 16-23,
Default: 23)
Console(config)#logging on 4-43
Console(config)#logging history ram 0 4-44
Console(config)#
Console#show logging flash 4-47
Syslog logging: Disable
History logging in FLASH: level errors