ADC EDU-409 Network Card User Manual


 
150-409-115-05, Issue 5 Functional Description
EDU-409 List 1 January 26, 2000 13
The capacities listed for the indoor enclosures in Table 5 assume no solar
load. The capacities listed for the outdoor enclosures in Table 6 assume a full
solar load as described above. The Recommended Slot Assignment for
Maximum Capacity column assigns slots according to the following thermal
stress reduction rules:
1 Always leave at least one empty slot between adjacent doublers. The
adjacency rule only applies to the left- and right-hand sides of the
doubler. The top of one unit can be adjacent to the bottom of another,
though the latter configuration should be avoided if possible.
2 Allow as much room as possible between doublers on all four sides.
Rule 1 does not apply to the HRE-458 and HRE-819 enclosures
since these products have the required slot separations
already built into their design.
Slot assignments that do not follow the recommended
configurations in Table 5 and Table 6 are permissible as long
as the above two rules are applied. Otherwise, damage may
occur to doubler units.
Table 5. Indoor Enclosure Capacities
Vendor Description Model #
EDU-409 List
1 Doubler
Capacity
239 T1
Repeater
Capacity
CHARLES Indoor wall mount CiAC2300 7 7
CiAC2002 2 2
SPC Indoor rack and wall
mount
4400-09 18 18