MICRO DOUBLER CAPACITY DEPLOYMENT
R
ULES
The deployment rules for micro doubler capacity are summarized below:
1 Use Table 5 on page 13 for indoor enclosures.
2 Use Table 6 on page 14 for outdoor enclosures with Full Solar Load for
ambient temperatures up to 46.1 °C maximum.
3 The capacities shown in Table 6 can be increased by two for non-solar
load (shaded or manhole applications).
4 Decrease capacities in Table 6 by one for every 2.7 °C increase, or
fraction thereof, in ambient temperatures above 46.1 °C.
5 Increase the capacities by one for every full +2.7 °C reduction in ambient
temperature below 46.1 °C.
6 Decrease any outdoor capacity by one for every four E1 repeaters, or
fraction thereof, that are installed with the doublers.
7 For all outdoor applications, decrease the capacity by one for every two
adjacent doublers that are not separated by at least one empty slot.