152-388-100-02, Issue 2 Provisioning
H2TU-C-388 List 1 June 6, 2000 13
PROVISIONING TASKS
After the HiGain Line Unit is successfully installed, perform these basic provisioning tasks:
1 Set the date and time (see “Setting Date and Time” on this page)
2 Set the circuit ID numbers (see “Setting Circuit ID Numbers” on page 14)
3 Make any necessary configuration changes (see “Configuring the System” on page 15)
4 Clear history, alarm, and event log screens to remove miscellaneous data during startup (see “Clearing the
History, Alarm, and Event Log Screens” on page 21)
Setting Date and Time
Figure 4. Configuration Menu - Date and Time
1 Type to select the Config menu.
2 Select Date and Time, then press .
3 Enter the date in the format indicated, then press .
4 Enter the time in the format indicated (entering seconds is optional), then press .
Monitor Performance Event Log Config Inventory Rlogon Help
+----------------------+
|
Standard Options -> |
| PairGain Options -> |
|
Date and Time -> |
+-------------------------------+
| Date (mm/dd/yyyy):
04/15/2000 |
| Time (hh:mm[:ss]): 12:30:01 |
+-------------------------------+
ID: xxxx--xxxx--xxxx--xxxx 04/15/00 12:30:01 H2TU-C S
y
stem: OK
C
ENTER
ENTER
ENTER